Capacitive level switch ( RF Admitance )

CAPACITIVE LEVEL SWITCH 300

Applications
Orion Capacitive is used to display (detect) levels of all kinds of powder and bulk solids material in any type of container or silos. It is a capacitive level switch with adjustable detection sensitivity.

Selection for application area

  • In construction industry for leveling of gypsum, lime, fine sand, dolomite, calcite, perlite, gypsum, cement, stone, coal, pulverized coal powder, etc.
  • In food industry for leveling of feed, seed, flour, salt, sugar, etc.

Functions
When the capacitive sensing type level switch’s probe which is located at the buttom of the instrument is sorrounded by the bulk solid material, there will be a decrease in emitted rf power. An output signal is generated when the amount of reduction is higher than the sensitivity setting. Detection sensitivity can be set up for all kind material depending on type and dielectric constant.

TECHNICAL FEACHURES / ELECTRICAL DATA

Connection terminals

Max. 2mm² (AWG 14) sectioned cable input. PG9

Signal delay

1 sec max

Sensitivity

Adjustable

Emited frequency

1,5MHz

Power supply

15..35VDC  1.2W

Signal output

Relays one change-over contact AC max. 250V, 2A, 500VA

Indicating light

Signal output and Diagnostic by built-in LEDs

Protection class

IP68 (cable cover fully closed, and by using a fitting 4 - 8mm thick and full-bored)

TECHNICAL FEATURES / MECHANICAL DATA

Housing

Cast aluminium enclosure IP68

Enclosure

IP 67 or EN 60529

Screw Material

Black anodized steel

Screw size

R 1½. Whitworth screw thread DIN 259

Probe Material

Delrin® POM-C EN 10204

Surface treatment

Electrostatic powder paint  RAL6014 over Noncorrosive alodine coating

Weight

0,8 kg

TECHNICAL FEATURES / OPERATING CONDITIONS

Ambient temp. (housing)

-20°C.. +60°C

Process temperature

-40°C.. +100°C

Min. density

50 g/l

Grain size

18mm Max.

Mechanical load

500N laterally (on probe)

Max. Tensile force

0.5kN

Max process pressure

10 bar

Max. Operating vibration 5-500Hz RMS random vibration 3G IEC-60068-2-64

 
CE DECLARATION

  • EN 61000-6-4:2001 Generic emission standard. Industrial environments.
  • EN 61000-6-2:2005 Generic immunity standard. Industrial environment.
  • EN 61010-1:2001 Safety requirements for electrical equipment for measurement, control, and laboratory use.