CAPACITIVE LEVEL SENSOR TRANSMITTER LVH500
Applications
Orion Capacitive is used to display (detect) levels of all kinds of powder and bulk solids material in any type of container or silos. It is a capacitive level switch with adjustable detection sensitivity.
Selection for application area
-
In construction industry for leveling of gypsum, lime, fine sand, dolomite, calcite, perlite, gypsum, cement, stone, coal, pulverized coal powder, etc.
-
In food industry for leveling of feed, seed, flour, salt, sugar, etc.
- Water Treatment Plants
Functions
When the capacitive sensing type level switch’s probe which is located at the buttom of the instrument is sorrounded by the bulk solid material, there will be a decrease in emitted rf power. An output signal 4-20mA is generated acording to the level . Detection sensitivity can be set up for all kind material depending on type and dielectric constant.
TECHNICAL FEACHURES / ELECTRICAL DATA
Connection terminals |
Max. 2mm² (AWG 14) sectioned cable input. PG9 |
Signal delay |
1 sec max |
Sensitivity |
Adjustable |
Emited frequency |
1,5MHz |
Power supply |
15..35VDC 1.2W |
Signal output |
Analogue Out 4-20mA 10Bit / Control Relay out contact AC max. 250V, 2A, 500VA |
Indicating light |
Signal output and Diagnostic by built-in LEDs |
Protection class |
IP68 (cable cover fully closed, and by using a fitting 4 - 8mm thick and full-bored) |
TECHNICAL FEATURES / MECHANICAL DATA
Housing |
Cast aluminium enclosure IP68 |
Enclosure |
IP 67 or EN 60529 |
Screw Material |
Black anodized steel |
Screw size |
R 1½. Whitworth screw thread DIN 259 |
Probe Material |
Delrin® POM-C EN 10204 |
Surface treatment |
Electrostatic powder paint RAL6014 over Noncorrosive alodine coating |
Weight |
0,8 kg |
TECHNICAL FEATURES / OPERATING CONDITIONS
Ambient temp. (housing) |
-20°C.. +60°C |
Process temperature |
-40°C.. +100°C |
Min. density |
50 g/l |
Grain size |
18mm Max. |
Mechanical load |
500N laterally (on probe) |
Max. Tensile force |
0.5kN |
Max process pressure |
10 bar |
Max. Operating vibration | 5-500Hz RMS random vibration 3G IEC-60068-2-64 |
CE DECLARATION
- EN 61000-6-4:2001 Generic emission standard. Industrial environments.
- EN 61000-6-2:2005 Generic immunity standard. Industrial environment.
- EN 61010-1:2001 Safety requirements for electrical equipment for measurement, control, and laboratory use.